5.5.12 P2 (High temperature protection of IPM module diagnosis and solution)

Description: If the temperature of IPM module is higher than setting value, the LED displays this failure code.
Possible defects:
• Faulty PCB
• Connection problems
Troubleshooting and repair:
Check the fastening screws on the PCB and IPM
radiator.
Are they fixed tightly?
YES
Replace the outdoor control PCB.
NO
Tighten the screws and apply silicon
grease.