STEP 2
Remove the
upper
rear cosmetic
panel
,
expose
the reel motor
mounting plate
.
This will
STEP 3
Place the reel
motor height
gauge
on the reel motor
mounting plate as
shown in
Figure 6
-
7
.
the reel motor
turntable
height
meets the
specification
criteria
.
Ensure
that
STEP 4
If
adjustment
is
necessary
,
loosen the
set screws
(
2 )
with the 2 mm hex driver
,
as required
.
Adjust
the turntable
height
6.5
.
3
Hours Meter Renewal Procedure
Necessary Tools
:
-
Phillips Head
Screwdriver
-
Torque Driver
(
Sony
#
J
-
6103
-
860
-
A )
Prerequisite
:
NONE
Specification
:
When the Hours Meter reches the end of it
' s cycle
( 5000 H ) it should be
replaced
.
However
,
if
the
user prefers
,
the meter can be
operated
in
the
reverse direction
by reversing
the two leads to the
meter
.
If
reverse direction performance of the
hours meter is desired
,
perform the procedure
shown
in the
steps
to follow
.
o
Turn the
APR
-
5000
power
switch OFF
.
STEP 1
Remove the two
securing
STEP 2
Open
the
ALN
panel
door
,
screws from the front of the
power supply
door and
The
power
supply
door is
hinged on the
bottom
open
,
edge
.
STEP
3
Remove the timer connector at CNJ
-
464 of the CSL
board
.
back onto the male connectors
,
signal
feed to the timer will cause the meter to
" count backward
"
from 5000
H
to zero hours
.
Rotate the
connector 180
-
degrees and
install
This reversal of the
Close the
power
supply
door and install the
securing
screws
.
STEP 4
Turn the
power
switch ON
.