Daily Checks - Panasonic HUSSMANN SMED153 Installation Manual

Medium temperature remote cabinet semi vertical display door cabinet
Table of Contents

Advertisement

CLEANING & MAINTENANCE
4.3

DAILY CHECKS

If an alarm system is not part of the refrigeration
installation, the temperature of each case should
be checked on a daily basis via the thermometer
that may be located in the left hand side of the
ceiling panel, or via another reliable method.
The case temperature should be in the range of
-2
C to +4
C (except during defrost).
0
0
Up to three separate readings may have to be taken
to ensure the case temperature isn't being taken
during a defrost cycle (which would give a higher
than desired reading).
If it is consistently outside this range, contact your
refrigeration service provider.
Visually check the case for damage or spills and
take appropriate remedial action.
Visually inspect drain strainer and drain for any
debris which could result in the drains becoming
blocked with the possibility of spilling on the floor
creating a slip hazard
If the cabinet is turned off during non trading hours
ensure the cabinet is cleaned thoroughly to avoid
bacterial growth during off time.
CAUTION:
components are identified during
inspection isolate case power and
contact service contractor.
CLEANING
A thorough cleaning and service of the case should
be carried out by qualified refrigeration and electrical
engineers on a six monthly basis. Please contact
Hussmann Pty Ltd or your service provider. Cases
should also be cleaned by store staff on at least a
weekly basis; some cases may, however, require more
frequent cleaning.
PAGE 30
If any damaged electrical
IMPORTANT NOTES
DO NOT use hot water on cold glass surfaces as the
glass may shatter and cause serious injury.
DO NOT use abrasive, solvent, ammonia or oil-
based cleaners.
DO NOT use steam or a high-pressure system to
clean the case.
When flushing the waste drain, do not use high
pressure water hoses and be careful not to
introduce water faster than the waste outlet/drain
can drain it.
DO NOT apply the detergents directly onto the
surfaces to be cleaned.
DO NOT use steam cleaning equipment.
DO NOT use excessive force.
DO NOT use high pressure cleaning equipment.
This may cause injury to the installer or user and
may damage cabinet.
SMED SEMI VERTICAL - HUSSMANN