22/33
Mounting, demounting and electric installation
Fig. 10-9: CDI+ cable with partially removed jacket
2. Remove the foil shield.
CDI+ cables are equipped with an additional foil shield. The foil
shield must not be used for the connection with the shielding clamp.
The foil shield is usually plastic-coated on one side for an improved
stability. The plastic coating is insulating.
Fig. 10-10: Foil shield of the CDI+ cable
Fig. 10-11: Foil shield removed
3. Fasten cable with EMC shielding clamp.
Fig. 10-12: CDI+ cable with shielding clamp
More shielding clamps:
Bosch Rexroth AG R911400465_Edition 01