STEP 1:
ASYD - System Data 1, Index 417, Bit 0: Recall Ringer Pattern for CALL BACK [C-1], CALL
WAITING - ORIGINATING [C-31], and OUTGOING TRUNK QUEUING [O-2]. 0/1 = Ringer
Pattern 5/Ringer Pattern 1.
System Data 3, Index 0. Timer Value for Ringer used for Ringer Pattern 0.
System Data 3, Index 1. Timer Value for Ringer used for Ringer Pattern 1.
System Data 3, Index 3.
Bit 0:
2 Burst (0.4 sec.-ON, 0.2 sec.-OFF, 0.4 sec.-ON) on the ON Time for Ringer Pattern 0. 0/1 =
Not Required/Required.
Bit 1:
2 Burst (0.4 sec.-ON, 0.2 sec.-OFF, 0.4 sec.-ON) on the ON Time for Ringer Pattern 1. 0/1 =
Not Required/Required.
Bit 5:
3 Burst (0.4 sec.-ON, 0.2 sec.-OFF, 0.8 sec.-ON, 0.2 sec.-ON, 0.4 sec.-OFF) on the ON Time
for Ringer Pattern 5. 0/1 = Not Required/Required.
System Data 3, Index 7. Timer Value for Ringer used for Ringer Pattern 5.
When the system data listed above is changed, circuit card (ELC) initialization is required.
STEP 2:
ASDT - Assign station data of the D
STEP 3:
ASFC - Assign Service Feature Class (SFC) that allows SFI = 148 (Personal Ringer) to the D
stations using this service.
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Personal Ringer
term
using this service.
P-59
term