Wiring Diagrams

Heat pump systems

Heat pump systems are specialty designed to be able to provide heating and
cooling using a single compressor, a reversing valve, and a fan.

Single Stage Heat Pump

Example:
Bosch Inverter Ducted Split
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, Y1, O/B and G wires from the heat pump to R/RC, C, Y,
O/B and G terminals on the wall plate, respectively
Single Stage Heat Pump
with Emergency Heat and Auxiliary Heat
Note:
W/E controls Emergency Heat output, and W2/AUX controls
Auxiliary Heat output.
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, W1, Y1, O/B and G wires from the heat pump to R/RC,
C, W/E, Y, O/B and G terminals on the wall plate, respectively
Connect jumper wire between W/E and W2/AUX.
R/RC
R/RC
R/RC
R/RC
27