Program 82 : Basic Hardware Setup for Extension

82-04 : SLIU Initial Data Setup

82-04 : SLIU Initial Data Setup
Level:
MF
Description
Input Data
Item No.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Conditions
Feature Cross Reference
970
Programming
Available.
Use Program 82-04 : SLIU Initial Data Setup to define the various basic timers for the ASTU
PCB.
Item
Companding method type
Ringing frequency
Minimum break time
Maximum break time
Minimum make time
Maximum make time
Minimum hook flash time
Maximum hook flash time
Minimum ground flash time
Minimum off-hook time
No detection time after off-hook
No detection time after pulse dial detection
Loop disconnect time, Reversal time
Ring, Message wait period time
None
None
Aspila EX
Input Data
0- u-law
1- A-law
0- 25Hz
1- 20Hz
2- 16Hz
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (5ms-1275ms)
1-255 (10ms-2550ms)
1-255 (5ms-1275ms)
Aspila EX Software Manual
Default
0 (u-law)
2 (16Hz)
2 (10ms)
20 (100ms)
2 (10ms)
20 (100ms)
21 (105ms)
200 (1000ms)
21 (105ms)
21 (105ms)
60 (300ms)
70 (350ms)
60 (600ms)
150 (750ms)