Figure 3-2
Dialog using the PLC of a SINUMERIK 840D sl as an example
2. Make the following settings in the "Extended download" dialog:
– PG/PC interface: Network card used, e.g. "Intel[R] Ethernet Connection I217-V"
– Connection with interface/subnet: Specific interface on the NCU or "Try all interfaces"
3. Click on "Start search" and then select the found PLC from "Compatible nodes in the target
subnet". Alternatively, you can specify an IP address directly in the "Compatible nodes in the
target subnet" list in the "Address" column.
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA
3.5 Load hardware configuration into the PLC
Configuring the NCU
41