Siemens SINUMERIK 840D sl Configuration Manual page 194

Sinumerik step 7 toolbox v15.1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Safety configuration
10.7 Configuring Safety Integrated (SPL)
Requirement
● The software options for Safety Integrated (SPL) are licensed and enabled in the associated
machine data.
● A maximum of three different F-source addresses are used in the configuration.
You can view the used F-source addresses in the PLC properties under "Fail-safe > F-
parameters". If more than three different F-source addresses are used, you must
standardize the F-source addresses because a maximum of 3 different F-source addresses
can be entered in the MD10385.
● The current configuration is compiled and loaded into the PLC.
● The MD10385, MD10386, MD10387, MD10388 and MD10389 machine data items are not
yet filled.
● No red LED illuminates on the F-peripherals.
If a red LED illuminates, check and correct the DIL switch setting or the F-source address,
e.g. using online diagnosis.
194
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA