Preliminary Rev.03
- Setting of LADDER EDITOR for Windows®
(1). Execute LADDER EDITOR for Windows® and go off-line mode.
(2). Choose [Environment Set] in [Utility] menu in the offline mode.
(3). Choose [Communication]dialog box.
A). Communication type
B). Host name
C). Port number
After setting, click [OK] button.
A).
(4).Choose [GRS] in [File] menu.
All setting are completed with this process.
After this, LADDER EDITOR for Windows® can communicate via EH-ETH in [Online] or {on-direct}
Caution
After setting Ethernet connection, it takes about 45 seconds to display "Communication Error" message in
the following cases. This happens because of Windows95, 98 internal processing.
(1). When the setting of EH-ETH is not correct, try to go [online] or [on-direct]. Otherwise the setting of PC
or LADDER EDITOR for Windows® is not correct, try to go [online] or [on-direct].
(2). Try to go [online] or [on-direct] to EH-ETH which power is off.
(3). Power off EH-ETH during communication.
(4). Change I/O assignment during communication.
(5). EH-ETH breaks down during communication.
(6). Put off or disconnect 10BASE-T cable during communication.
The contents of this manual might be changed without notice.
Chapter 6 Task code communication
: Ethernet
: EH-CPU448C (Name in Hosts file )
: 3004
6-7