7.11.2
Configuring drives with SINAMICS Integrated isochronously
Requirements
● STEP 7 , V16 or higher
● SINAMICS Startdrive , V16 or higher
Procedure
1. Add a SIMATIC Drive Controller to your project.
The network view displays the components of a SIMATIC Drive Controller: SIMATIC S7-
1500 CPU and SINAMICS Integrated, networked through PROFIdrive Integrated.
Figure 7-30
SIMATIC Drive Controller in the network view
SIMATIC Drive Controller
System Manual, 11/2019, A5E46600094-AA
Configuring
7.11 Configuring the clock system