Installing CFP Optical Modules
Remove the dust-proof plug from the CFP cage of the board.
Push the CFP optical module into the cage horizontally.
Pull the two screw rods outwards and ensure that the rods are
free. Then, partially tighten the rod on one side.
Completely tighten the rod on the other side, and then tighten
the rod that is partially tightened.
NOTE
If the CFP optical module is placed towards the cage but
cannot be inserted into the cage, the module insertion
direction is incorrect. When this occurs, rotate the module
by 180°and then re-insert it.
If insertion cannot continue after the CFP optical module
is pushed into the cage, the CFP optical module contacts
well with the board connector inside the cage.
After the installation is completed, check that the screws
are fastened properly.
M3
2# screwdriver
0.51±0.05 N· m
50
CFP optical module