Bosch Conettix B465 Installation And Operation Manual page 85

Universal dual path communicator
Hide thumbs Also See for Conettix B465:
Table of Contents

Advertisement

Conettix Universal Dual Path Communicator
Heartbeat
LED
Flashing
Flashing
Flashing
Flashing
Tab. 11.11: POWER LED descriptions
POWER LED
Flash pattern
On Steady
Flashing
Bosch Security Systems, Inc.
RX LED
Off
Off
Off
Off
Function
Indicates a good Input Power level.
Indicates Input Power is low (brownout) or failure.
Installation and Operation Manual
Maintenance and troubleshooting | en
Plug-in Status LED
Flashing (two flashes)
Flashing (three flashes)
Flashing (four flashes)
Flashing (five flashes)
85
Function
Indicates a cellular IP
address error. Check
with your service
provider to make sure
the cellular module
was setup correctly.
Indicates the SIM
Card is missing. Verify
the SIM card is
inserted into the
B442 or B443 cellular
communication
module. Refer to the
SIM card, page 90
troubleshooting
section for more
information.
Indicates a SIM Card
lockout. This requires
that the SIM PIN be
used to unlock the
SIM card.
Indicates an invalid
SIM PIN. Verify the
correct SIM PIN was
entered.
Refer to the PIN code,
page 90
troubleshooting
section for more
information.