TERMINAL BOARD LAYOUT DRAWING

Strip X1
Function
1
Programmable/configurable analog differential input. Signal: terminal 1.
Analog input 1
2
Reference point: terminal 2. Default setting: Ramp ref 1
3
Programmable/configurable analog differential input. Signal: terminal 3.
Analog input 2
4
Reference point: terminal 4. Default setting: none
5
Programmable/configurable analog differential input. Signal: terminal 5.
Analog input 3
6
Reference point: terminal 6. Default setting: none. (1)
7
Reference voltage +10V; Reference point: terminal 9
+10V
8
Reference voltage -10V; Reference point: terminal 9
-10V
9
Internal 0V and reference point for±10V
0V
Enable/
12
Digital input 0
13
Programmable inputs,
14
Default=none
15
16
COM D I/O
Reference point for digital inputs and outputs,term.12...15, 36...39, 41...42
18
Reference point for + 24V OUT supply, terminal 19
0 V 24
19
+24V supply output. Reference point: terminal 18 or 27 or 28
+24V OUT
Analog output
21
Program.analog output; def.setting: none
1
22
0V
Internal 0V and reference point for terminals 21 and 23
Analog output
23
Program.analog output; def.setting: none
2
BU comm.
26
VeCon controlled BU-32 braking units command. Ref. point: term.27.
output
27
0 V 24
Reference point for BU-32 command, terminal 26
28
RESERVED
29
RESERVED
36
Digital input 4
37
Digital input 5
Programmable digital inputs; default setting: none
38
Digital input 6
39
Digital input 7
Digital output
41
2
Programmable digital outputs; default setting: none
Digital output
42
3
Supply D O
46
Supply input for digital outputs on terminals 41/42. Ref. point: term.16.
78
Motor PTC
Motor PTC sensing for overtemperature (cutoff R1k if used)
79
Strip X2
Function
80
Digital output 0
Potential- free relay contact, programmable output,
Relay
82
Default=Drive OK when closed
83
Potential- free relay contact, programmable output,
Digital output 1
Default=Speed is zero when closed
Relay
85
GE Industrial Systems
E
F
G
H
—————— Block Diagrams ——————
I
J
K
L
PRODUCT:
AV-300i AC flux vector Drive
Salem, Va. USA
Proprietary Information
Do Not Copy
M
N
O
P
01
02
max
03
±10V
0.25mA
04
(20mA when
current loop
input)
05
+10V/10mA
-10V/10mA
06
-
+30V
07
3.2mA @ 15V
5mA @ 24V
08
6.4mA @ 30V
-
09
-
+22 28V
120mA @ 24V
10
±10V/5mA
-
11
±10V/5mA
+28V/15mA
12
-
-
13
+30V
14
3.2mA @ 15V
5mA @ 24V
6.4mA @ 30V
15
+30V/40mA
16
+30V/80mA
1.5mA
17
Max.
18
250V AC
1 A
19
250V AC
1 A
20
File name:
TB_Layout.vsd
Issued Date
10/15/99 -- RM
Initials:
03/02/00 -- RNC