Sony DVCAM DSR-PDX10 Service Manual page 192

Hide thumbs Also See for DVCAM DSR-PDX10:
Table of Contents

Advertisement

1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
Note1: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2: Before performing the adjustments, check the data of page: 0,
address: 10 is "00". If not, set data: 00 to this address.
Note3: As the PANEL CLOSE switch is attached to the cabinet (R), this
cabinet must be attached when performing adjustments.
If you perform the adjustments with cabinet (R) removed, set the
following data.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
Note4: NTSC model: DSR-PDX10
PAL model: DSR-PDX10P
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN1008 of VC-318 board.
Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-A).
The following table shows the Pin No. and signal name of CN1008.
Pin No.
Signal Name
1
EVF VB
3
EVF LED DA
5
EVF VCO
7
MD2
9
XINIT
11
DRUM ON
13
REC CRRT1
15
REG GND
17
SWP
19
GND
Table. 6-1-12.
CN1008
19
Fig. 6-1-24.
Pin No.
Signal Name
2
D 2.8V
4
EVF VG
6
EVF VR
8
XCS MC FLASH
10
XCS ST IMAGE IC
12
FRRP
14
REC CRRT0
16
HI XRESET
18
RF IN
20
RF MON
1
2
20
1. VCO Adjustment (DB-016 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: The data of page: 0, address: 10 must be "00".
Adjusting method:
Order Page Address Data
1
0
01
2
C
51
3
C
51
4
C
51
5
6
7
8
C
52
9
0
01
Note2: Refer to "Table 6-4-1. Hexadecimal-decimal Conversion Table".
6-37
DSR-PDX10/PDX10P
Camera
Arbitrary
Pin 5 of CN1008 of VC-318 board
(EVF VCO)
Frequency counter
C
51, 52
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Procedure
01
Set the data.
Change the data and set the
VCO frequency (f) to the
specified value.
Press PAUSE button.
Read the data, and this data is
named D
.
51
Convert D
to decimal notation,
51
and obtain D
'. (Note2)
51
Calculate D
' using following
52
equations (Decimal calculation)
[NTSC model]
When D
' 231
51
D
'=D
'+24
52
51
When D
'>231
51
D
'=255
52
[PAL model]
When D
' 24
51
D
'=D
'-24
52
51
When D
'<24
51
D
'=0
52
Convert D
' to a hexadecimal
52
number, and obtain D
. (Note2)
52
D
Set the data, and press PAUSE
52
button.
00
Set the data.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvcam dsr-pdx10pDvcam rmt-811

Table of Contents