16. Angular Velocity Sensor Sensitivity Adjustment
Perform this adjustment only when replacing the angular
velocity sensor. When the microprocessor, circuit etc. is
damaged, don't perform this adjustment but check the
operations only.
Note down the sensitivity displayed on the angular velocity
sensor of the repair parts. At this time, note down also to which
board it was attached to.
Be sure to check because if attached incorrectly, the screen
will vibrate up and down or left and right during the steady
shot operations.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03MA
Type B: ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during steady shot operations. After replacing, re-adjust
according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Switch setting:
1) POWER .................................................................. CAMERA
2) ZOOM .................................................................... TELE end
3) STEADY SHOT (Menu display) ..................................... OFF
Adjustment Page
Adjustment Address
Note: The sensor sensitivity of SE4001 and SE4002 of the SE-132 board
is written only on the repair parts.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the sensor sensitivity written on SE4001 (PITCH sensor)
of the SE-132 board, and name this as S
3) Read the sensor sensitivity written on SE4002 (YAW sensor)
of the SE-132 board, and name this as S
4)
Read the data of page: F, address: 84, and name this data as
D
.
84
5)
Read the data of page: F, address: 85, and name this data as
D
.
85
6)
Convert D
and D
84
85
D
' (Refer to Table 6-4-1. "Hexadecimal-Decimal conversion
85
table" of "6-4. Service Mode".)
7) Calculate D
' and D
86
87
calculation).
'/128) × (0.60 / S
D
' = (D
86
84
' × 0.4125 / S
= D
84
' / 128) × (0.60 / S
D
' = (D
87
85
' × 0.4125 / S
= D
85
8) Convert D
'and D
' into hexadecimal digits, to obtain D
86
87
and D
. (Round off decimal points.)
87
(Refer to Table 6-4-1. "Hexadecimal-Decimal conversion table"
of "6-4. Service Mode".)
9) Select page: F, address: 86, set data: D
button.
10) Select page: F, address: 87, set data: D
button.
Processing after Completing Adjustments
1) Select page: 0, address: 01, and set data: 00.
2) Check that the steady shot operations have been performed
normally.
F
86, 87
.
4001
.
4002
into decimal digits, to obtain D
' using the following equation (decimal
× 88
4001)
4001
) × 88
4002
4002
, and press the PAUSE
86
, and press the PAUSE
87
17. Mechanical Shutter Adjustment
Adjust the close time and loss time every F number of the mechanical
shutter and high-speed shutter correction value to correct the
luminous exposure.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
camera direction so that the whole screen is white.
Note2: This adjustment should be carried out upon completion of the
following adjustments.
"HALL Adjustment", "Flange Back Adjustment", "F No. &
ND Light Quantity Standard Data Input"
Note3: The data of page: 0, address: 10 must be "00".
Switch setting:
1) POWER .................................................................. CAMERA
2) ZOOM .................................................................... WIDE end
3) DIGITAL ZOOM (Menu display) ................................... OFF
4) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
2
6
3
6
4
5
6
6
6
7
6
Note4: The adjustment data will be automatically input to page: F, address:
90 to A5.
Processing after Completing Adjustments
Order Page Address Data
' and
84
1
6
2
6
3
6
4
0
86
6-34
Clear chart (All white) (Note1)
(Approx. 33cm from the front of the lens)
Adjustment remote commander
F
90 to A5
Data of page: 6, address: A8 is "00".
Procedure
01
01
Set the data.
30
01
Set the data.
9C
01
Set the data.
Wait for 1sec.
01
AD
Set the data, and press PAUSE
button.
02
Check that the data changes to
"01". (Note4)
A8
Check that the data is "00".
Procedure
01
00
Set the data, and press PAUSE
button.
30
00
Set the data.
9C
00
Set the data.
01
00
Set the data.