Link Change - Siemens SCALANCE W1780 Configuration Manual

Industrial wireless lan
Table of Contents

Advertisement

Configuring with Web Based Management
6.5 "System" menu
Procedure
1. Click the check box in front of the line name you want to monitor to enable or disable the
monitoring function.
2. From the "PROFINET Redundancy" drop-down list, select the desired entry for redundant
power supply to be monitored by PROFINET.
3. Click the "Set Values" button.
6.5.15.2

Link Change

Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
● when there should be a link on a port and this is missing.
● or when there should not be a link on a port and a link is detected.
If a fault occurs, the error LED lights up on the device. The currently pending fault is displayed
under "Information > Faults".
In addition, the corresponding error message is entered in the result log table. The content of
the event log table is displayed in "Information > Log Tables > Event Log".
206
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03