Table 2 has the following columns:
● Event
The column contains the following values:
– Cold/warm restart
– Link Change
– Authentication Failure
– Power Change
– Spanning Tree Change
– Fault State Change
– Overlap AP Detection (only in access point mode)
– WDS (Only in access point mode)
– DFS (Only in access point mode)
– WLAN Authentication Log
– WLAN De/Authentication (Only in client mode)
– WLAN General (Only in access point mode)
– Configuration Change
– Service Information
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
The device was turned on or restarted by the user.
This event occurs only when the port status is monitored and has changed, see "System
> Fault Monitoring > Link Change".
This event occurs when attempting access with a bad password.
This event occurs only when power supply lines 1 and 2 are monitored. It indicates that
there was a change to line 1 or line 2. The event occurs when the PoE power supply has
failed, see "System > Fault Monitoring > Power Supply".
The STP or RSTP or MSTP topology has changed.
The fault status has changed. The fault status can relate to the activated port monitoring,
the response of the signaling contact or the power supply monitoring.
This event is triggered when there is an entry in the "Overlap AP" list.
The connection status of a WDS link has changed.
This event occurs if a radar signal was received or the DFS scan was started or stopped.
Forwarding of the entries from the WLAN authentication log to the system protocol
server.
With successful or failed WLAN authentication attempts.
This event occurs if the channel bandwidth has changed.
This event occurs when the configuration of the device has changed.
Some system events that occurred are entered in the event log table without
configuration. For these events, you can configure additional types of notification.
Configuring with Web Based Management