1-1. Operating Environment

Operating guaranteed temperature :
Performance guaranteed temperature : +10 dC to +35 dC
Operating humidity :
(relative humidity)
Storage temperature :
Mass (when all options are installed) :
MFS-2000 :
Approx. 22 kg
MKS-2010 :
Approx. 10.3 kg
MKS-2015 :
Approx. 11.3 kg
MKS-2017 :
Approx. 12.6 kg
Prohibited locations for installation
. Areas where the unit will be exposed do direct sunlight
or any other strong lights
. Dusty areas
. Areas subject to vibration
. Areas with strong electric or magnetic fields
. Areas near heat sources
. Areas subject to electrical noise
. Areas subject where is subjected to static electricity
Ventilation of the processor
The inside of the processor is cooled by a fan (on both
sides).
The power supply can be damaged if the exhaust vent (on
both sides) and air intake (on the front panel) are blocked
or the fan is stopped.
Therefore, leave room of more than 10 cm in the front and
both sides of the processor.
Ventilation of the control panel
The inside of the control panel is cooled by a fan (on the
side).
The power supply can be damaged if the exhaust vent and
air intake (on both sides and the rear) are blocked or the
fan is stopped.
Therefore, leave room of more than each 10 cm in the
front, back, right and left sides. (There is no need of
leaving room on the left side of the MKS-2017.)
When you install the control panel to the rack, be sure not
to block the exhaust vent/air intake on the sides of the
control panel.
MFS-2000 IM
Section 1

Preparation for Installation

1-2. Power Supply

+5 dC to +40 dC
w
There is no power switch on the control panel.
10 % to 90 %
Set the dedicated breaker.

1-2-1. Power Specifications

_20 dC to +60 dC
The switching regulator is used for the power of the
processor and the control panel. The voltage within the
range of 100 V to 240 V can be used without changing the
supply voltage.
Power requirements :
Power frequency :
Current consumption (when all options are installed) :
m(Processor)
. As the inrush current at turn-on is a maximum 12 A (at
. The processor contains the two power supply units as the
n(Control panel)
. As the inrush current at turn-on is a maximum 12 A (at
MFS-2000 :
4.5 - 2.1 A
MKS-2010 :
1.0 - 0.5 A
MKS-2015 :
1.0 - 0.5 A
MKS-2017 :
1.0 - 0.6 A
100 V)/33 A (at 230 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source breaker will operate or the unit will
abnormally operate.
standard configuration. A maximum of three power
supply units may be installed. When starting up the
processor, be sure to turn on the power of two or more
power supply units.
100 V)/28 A (at 230 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source breaker will operate or the unit will
abnormally operate.
AC 100 - 240 V
50/60 Hz
1-1