Conversion to another type of gas

Checking the first intake of air

a Retaining screw
b Air intake sleeve
Gap X must measure:
For natural gas: 13 mm
For ULPG gas: 13 mm
To set gap X
 Loosen the retaining screw  and
slide the air intake sleeve .
 Then screw the retaining screw back
on.
58

Changing the small jets

a Small diameter jet
(e.g. for ULPG gas: 0.23)
b Large diameter jet
(e.g. for ULPG gas: 0.60)
 Using a small screwdriver, unscrew
the two small jets  and  in the gas
fitting.
 Pull out the jets with a pair of pliers.
 Fit the new jets securely (see jet ta-
ble).
 Secure the jets against inadvertent
loosening with sealing wax.