The Crane control program supports programmable digital inputs with a (PTR) logic
with sign.group.index.bit (+.000.000.00).

Additional information for Digital Inputs and Pointers PTR

+001.017.00 Values of standard Digital Inputs on RMIO board
DIL D16-1 STATUS
RMIO DI1 = +001.017.00
RMIO DI2 = +001.017.01
RMIO DI3 = +001.017.02
RMIO DI4 = +001.017.03
RMIO DI5 = +001.017.04
RMIO DI6 = +001.017.05
RMIO DIL = +001.017.06 (Power ON acknowledge), programmable with parameter 97.18
+001.040.00 Values of optional Digital Inputs on RDIO board
DI15-7 STATUS
RDIO DI7 = +001.040.00
RDIO DI8 = +001.040.01
RDIO DI9 = +001.040.02
RDIO DI10 = +001.040.03
RDIO DI11 = +001.040.04
RDIO DI12 = +001.040.05
RDIO DI13 = +001.040.06
RDIO DI14 = +001.040.07
RDIO DI15 = +001.040.08