116
The (42.16) BRK REOPEN DELAY can be used for a safety purpose in the event of
a frequent Start -> Stop -> Start sequence. This parameter delays the opening of the
brake when a Start command is issued immediately after a stop sequence.
Settings
Parameter
14.01
Group
Diagnostics
Actual signal
03.01
03.13 bit 6
03.32 bit 9
Warnings
BRAKE ACKN
BRK LONG TIME
BRAKE SLIP FLT
Faults
BRAKE ACKN
Reduced run function
The Reduced run function is available for parallel-connected inverters. The function
makes it possible to continue the operation with limited current if an inverter
module(s) is out of order. If one of the modules is broken, it must be removed.
Parameter change is needed to continue the run with reduced current
CONFIG USER). For instructions on how to remove and reconnect an inverter
module, see the appropriate drive hardware manual.
Program features
Additional information
Relay output for the brake control (set to BRAKE CTRL)
42 BRAKE CONTROL
Brake function settings
Additional information
Ramp in zero bit
The state of bit "brake Open/Close command"
The brake long time active bit
Unexpected state of Brake Acknowledge signal
Brake closing sequence not completed and drive active with zero
speed reference
Brake slip detected during starting sequence when the brake is closed
Unexpected state of Brake Acknowledge signal
(95.03
INT