Group 3-Diagnostic Screens; Group 4-Event Log - GE MDS 4790 Series Installation & Operation Manual

400 mhz/900 mhz multiple address system master station radio
Table of Contents

Advertisement

MDS 05-3438A01, Rev. F
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8457-MDS-UP-9790X.aspx
Group 3—Diagnostic Screens
The Diagnostic screens display important status information for the
local and remote radio, as well as run several tests useful in locating
system problems.
Group 4—Event Log
The event log lists up to 800 of the most recent operating changes. These
events include system problems, as well as normal operator actions
such as turning the power on or off.
The following table organizes front panel screens in the same way as the
PC commands described earlier in this manual: operating parameters,
diagnostics, and radio information.
Table 15. Front Panel Screens—Configuration Parameters
FRONT PANEL
TERMINAL
SCREEN
COMMAND
Access Level
Details, page 68
Alarm Masks
AMASK [0000
Details, page 75
0000–FFFF FFFF]
Details, page 40
NMASK [0000
0000–FFFF FFFF]
Details, page 49
ASENSE [HI/LO]
Details, page 41
Battery Backup
BATT(ery) [ON/OFF]
Details, page 73
Details page 41
Backlight Intensity
Details, page 76
Baud Rate/Format
BAUD [xxxxx abc]
Details, page 70
Details, page 42
Clear-to-Send Delay
CTS [0-255]
Details, page 70
Details, page 43
Continuous Keying
CKEY [ON/OFF]
Details, page 72
Details, page 43
Data Buffering
BUFF [ON/OFF]
Details, page 74
Details, page 42
Display Contrast
Details, page 75
Emphasis
EMP [ON/OFF]
Details, page 70
Details, page 46
Key On Data
DATAKEY [ON/OFF]
Details, page 73
Details, page 44
Multi-Drop Address
MADDR [NONE, 1–255]
(MADDR)
Details, page 48
Details, page 72
Manual Key
DKEY
Details, page 72
Details, page 45
KEY
Details, page 47
MDS 4790/9790 Series I/O Guide
(Page
77)
(Page
79)
DESCRIPTION
Enable or disable configuration mode.
Set or show hexadecimal code identifying
whether alarm events cause an alarm output
relay to assert and cause the active radio to
switch over; also displays the alarm sense.
Enable or disable alarm generation when the
back-up battery falls below 13.0 Vdc.
Set or show front panel display's background
brightness.
Set or show data interface port communica-
tion attributes.
Set or show the time to wait after RTS is
asserted by the host computer before assert-
ing the CTS line.
Select continuous or non-continuous keying.
Enable or disable data buffering.
Set or show front panel display's foreground
character intensity.
Enable or disable pre-emphasis and
de-emphasis.
Set or show keying behavior (key-on-data or
key-on-RTS).
Unit address for use with MDS' InSite NMS
software, where multiple master stations are
connected at one location.
Manually key or dekey the transmitter.
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents