Table 11.Minor Alarm Conditions' Hexadecimal Values
Alarm Code
(HEX)
0000 8000
0000 0000 0000 0000 1000 0000 0000 0000
0000 4000
0000 0000 0000 0000 0100 0000 0000 0000
0000 2000
0000 0000 0000 0000 0010 0000 0000 0000
0000 0800
0000 0000 0000 0000 0000 1000 0000 0000
0000 0015
0000 0016
0000 0040
0000 0000 0000 0000 0000 0000 0100 0000
0000 0020
0000 0000 0000 0000 0000 0000 0010 0000
0000 0010
0000 0008
0000 0001
0000 0000 0000 0000 0000 0000 0000 0001
Monitoring Alarms
on the Standby
Radio
MDS 05-3438A01, Rev. F
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-8457-MDS-UP-9790X.aspx
Code values for individual minor alarm conditions are
given below:
Alarm Code
(Binary)
There is a limited ability to monitor alarms on the standby radio without
using InSite software. You accomplish this using the command line
interface.
The
,
, and
ALARM
STAT
SER
• If you enter the command without the parameter, the response
applies to the active radio.
• If you enter the command with the
always applies the the
MDS 4790/9790 Series I/O Guide
Event
Description
Code
16
The unit address has not been
programmed.
17
A data parity fault has been detected
on the DB25. This usually means there
is a parity setting mismatch between
the radio and the RTU.
18
A data framing error has been
detected on the DB25. This
sometimes means there is a baud rate
mismatch between the radio and the
RTU.
20
Configuration error. The modem
setting is incorrect.
21
Unit is running on back-up battery
power.
22
Standby radio hardware not installed
or available.
25
The 10-volt power regulator output is
out of tolerance. If the voltage is too far
out of tolerance, the radio might not
work.
26
The DC input supply voltage is out of
tolerance. If the supply voltage is too
far out of tolerance, the radio might not
work.
27
LNA current fault (LNA current is out of
range).
28
Total board current fault (total board
current is out of range).
31
The radio's internal temperature is
approaching an out-of-tolerance
condition. If the temperature drifts
outside of the recommended
operating range, the radio might not
work.
commands take an optional parameter
parameter, the response
[A]
radio.
A
:
[A | B]
39