Table 6- 8
Technical specifications of motor reactors, 3 AC 380 V – 480 V, Part 2
Order number
Suitable for Motor Module
Unit rating of the Motor Module
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- to the Motor Module
- load
- PE
Max. permissible cable length
between motor reactor and motor
- with 1 motor reactor
- with 2 motor reactors in series
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
Table 6- 9
Technical specifications of motor reactors, 3 AC 500 V – 690 V, Part 1
Order number
Suitable for Motor Module
Unit rating of the Motor Module
Rated current
Power loss
- at 50 Hz
- at 150 Hz
Connections
- to the Motor Module
- load
- PE
Max. permissible cable length
between motor reactor and motor
- with 1 motor reactor
- with 2 motor reactors in series
Degree of protection
Dimensions
Width
Height
Depth
Weight, approx.
Chassis Liquid Cooled Power Units
Manual, (GH7), 01/2011, 6SL3097-4AM00-0BP1
6SL3000-
2AE36-1AA0
6SL3325-
1TE36-1AAx
kW
315
A
605
kW
0.798
kW
0.9
M12
M12
M10
m
m
IP00
mm
410
mm
392
mm
292
kg
130
6SL3000-
2AH31-0AA0
6SL3325-
1TG31-0AAx
kW
90
A
100
kW
0.269
kW
0.3
M10
M10
M6
m
m
IP00
mm
270
mm
248
mm
200
kg
25
Motor-side power components
2AE38-4AA0
2AE41-0AA0
1TE38-4AAx
1TE41-0AAx
450
560
840
985
0.834
0.939
0.943
1.062
M12
M12
M12
M12
M10
M10
300 (shielded) / 450 (non-shielded)
525 (shielded) / 787 (non-shielded)
IP00
IP00
410
392
292
140
146
2AH31-5AA0
2AH32-4AA0
1TG31-5AAx
1TG32-2AAx
132
200
150
215
0.296
0.376
0.332
0.425
M10
M10
M10
M10
M6
300 (shielded) / 450 (non-shielded)
525 (shielded) / 787 (non-shielded)
IP00
IP00
270
248
200
25.8
6.2 Motor reactors
2AE41-4AA0
1TE41-4AAx
800
1405
0.946
1.054
2 x M12
2 x M12
M10
IP00
410
460
392
392
302
326
179
2AH33-6AA0
1TG33-3AAx
315
330
0.4
0.454
M10
M10
M6
M6
IP00
300
300
285
285
212
212
34
46
181

Advertisement