X1 braking resistor connection

Table 6- 1
X1 braking resistor connection
Terminal
1
2
Type: Screw terminal 4 (Page 172)
Max. cross-section that can be connected: 4 mm
Table 6- 2
Braking resistors without a thermostatic switch for Braking Modules
Braking resistor
6SN1113-1AA00-0DA0
6SL3100-1BE31-0AA0
For detailed technical information on the braking resistors, see the section entitled Braking
resistors (Page 117).
High Frequency Drive
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
Designation
Braking resistor connection R1
Braking resistor connection R2
2
R in Ω
17
5,7
6.1 Braking Module Booksize
Technical data
Continuously short-circuit proof
P
in kW
N
0,3
1,5
Braking Modules
P
in kW
max
25
100
91