Technical Data - Siemens SINAMICS S120 System Manual

High frequency drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

8.8

Technical data

8.8.1
Technical data
Table 8- 7
Technical data
6SL3100-1DE22-0AA1
Input data, AC input
Line voltage
Line frequency
Rated input current
Rated value (at V
)
E rated
Starting current inrush
Input data, DC input
Rated input voltage
Input voltage range
DC link voltage
(continuous input voltage)
Supply current (at 600 V)
Overvoltage tripping
Undervoltage tripping
Output data
Rated output voltage V
A rated
Rated output current I
A rated
Rated output power P
A rated
Overcurrent limitation for short-circuit
Surge suppression
Current carrying capacity of the 24 V busbar
Residual ripple (clock frequency approx. 50 kHz)
Switching peaks (bandwidth 20 MHz)
Power loss ride-through (at 400 V AC)
Power loss
Line
DC link
Efficiency
Circuit breaker (UL)
Type designation:
Rated current:
Resulting rated short-circuit current
SCCR at 480 V AC:
High Frequency Drive
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
1)
Unit
Value
V
3 AC 380 ... 480 ± 15 %
AC
Hz
45 ... 66
A
≤ 2
AC
A
≤ 28 at > 5 ms
AC
V
600
DC
V
300 ... 882
DC
V
430 ... 800
DC
300 ... 430 < 1 min
800 ... 853 < 1 min
853 ... 882 < 10 s
A
1.1
DC
V
> 882
DC
V
280 ± 3 %
DC
V
24 ... 28.8
DC
A
20
DC
W
520
A
approx. 23
DC
V
< 35
A
20
DC
mV
< 100
pp
mV
< 200
pp
ms
5
W
70
W
65
%
> 83
3RV1021-1DA10
A
2.2 ... 3.2 (setting value 3)
kA
100
Control Supply Module (CSM)