4 Repair
4.3.1 Replacement of cable harness, axes 1-4
Continued
9
10
11
12
13
14
Continues on next page
240
Action
Reconnect connectors R2.SMB, R1.SMB1-3,
R1.SMB4-6 to the SMB unit.
Reconnect X8, X9 and X10 if the brake release
board is located in frame.
Reconnect R1.G if it has been disconnected.
Secure the SMB cover with its attachment screws.
If cabling is used for 7th axis (option), refit the
connector R2.FB7 to the SMB cover and tighten
with 6 Nm.
WARNING
Before continuing any service work, please ob-
serve the safety information in section
release buttons may be jammed after service work
on page
232!
Pull the cable harness through the lower arm.
Refit the cable gland securing the cables inside
the lower arm.
Refit the cable gland securing the cables to the
arm house.
Make sure not to twist the harness!
© Copyright 2007 - 2018 ABB. All rights reserved.
Note
xx0200000118
The brake
xx0100000142
xx0100000143
Product manual - IRB 7600