Commissioning
5.4 Creating a project offline in Startdrive
4. In the device view, click the infeed. Make sure that you click in the white area of the
infeed.
5. In the secondary navigation of the inspector window, select "Line Module - Selection –
ALM"
6. Select your infeed in the list based on the article number.
Figure 5-8
The unspecified infeed is assigned the data of the selected infeed.
The white area turns dark gray.
The DRIVE-CLiQ-connection between the interfaces X100 and X200 is drawn as default
setting.
Result
The infeed unit is inserted and specified.
Connecting infeed units in parallel
To connect infeed units (Line Modules) in parallel with already added modules, proceed as
follows:
1. Open the "Line Modules" entry in the hardware catalog.
2. If you have not yet inserted any infeed unit, drag the desired, non-specified infeed unit
into the device view and specify this infeed unit.
74
Line Module selection
Getting Started, 12/2018, 6SL3097-5AG30-0BP0