Performing basic parameterization
6.3 Drive axes
Number Designation
p1120
Ramp-up time
p1121
Ramp-down time
p1135
OFF3 ramp-down
time
Precondition
● You have completely specified and configured the motor used in the device configuration
of the drive axis.
Note
This basic parameterization cannot be performed without having completed this full
configuration.
6.3.2.5

Optimization runs

Using the "Optimization run" function, you can calculate motor and controller data for motors
in the motor list as well as for non-listed motors.
Preconditions
● You have completely specified and configured the motor used in the device configuration
of the drive axis.
Note
Specifying third-party (non-listed) motors
When third-party motors are specified, the motor data must be manually entered (see
Chapter "Inserting and specifying motors that are missing from the motor list (Page 89)").
Note
This basic parameterization cannot be performed without having completed this full
configuration.
152
Description
Ramp-up/ramp-down time always refers to the time interval from motor standstill to the set
maximum speed (without using roundings).
The OFF3 ramp-down time is effective from the maximum speed down to the motor
standstill.
"Drive axis > Parameters > Basic parameterization > Optimization runs"