DC link components

5.2 Braking resistors

5.2
Braking resistors
5.2.1

Description

The excess energy of the DC link is dissipated via the braking resistor.
The braking resistor is connected to a Braking Module. The braking resistor is positioned
outside the cabinet unit or switchgear room. This enables the resulting heat loss around the
Basic Line Modules, Smart Line Modules, Active Line Modules, or Motor Modules to be
dissipated. This reduces the level of air conditioning required.
Resistors with rated powers of 25 kW and 50 kW are available.
Greater outputs can be implemented by connecting Braking Modules and braking resistors in
parallel. In this case, the Braking Modules are installed in the air duct of the Basic Line
Modules, Smart Line Modules, Active Line Modules, or Motor Modules. Depending on the
size of the respective module, up to three mounting locations are available.
Since the braking resistors can be used in converters with a wide voltage range, the voltage
can be adjusted (for example, to reduce the voltage stress on the motor and converter) by
setting the response thresholds on the Braking Module.
A thermostat monitors the braking resistor for excessively high temperatures and issues a
signal on a floating contact if the limit value is exceeded.