Drive-Cliq Interfaces X400, X401, X402 - Siemens SINAMICS S120 Equipment Manual

Chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules
4.3 Interface description
4.3.9

DRIVE-CLiQ interfaces X400, X401, X402

Table 4- 9
DRIVE-CLiQ interfaces X400, X401, X402
PIN
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interface: Yamaichi, order no.: Y-ConAS-13
156
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
24 V power supply
Electronics ground
Manual, (GH3), 10/2008, 6SL3097-2AE00-0BP3