Oam Cli Commands; Loopback; Table 221 Loopback Command - Nokia 7302 Basics, Management And Oam Manual

Intelligent services access manager/fttn/fx, fd 100/320gbps nt and fx nt ihub system
Hide thumbs Also See for 7302:
Table of Contents

Advertisement

Ethernet Connection Fault Management
(2 of 2)
8.12.2
8.12.2.1
Table 221
(1 of 2)
190
Item
Description
Description
The value of measurement-period specifies the time after which the synthetic loss calculation
is made periodically. If the value of this object is set to 'X' seconds, loss measurement
calculations are done after every 'X' seconds. This includes the default SLM timeout of 5
seconds in which the agent will not transmit any further SLM PDUs and will wait for the
response from remote node. Upon the expiration of the timeout, the agent assumes that the
message response will not be received. Any response received after the timeout period has
expired is silently discarded. This parameter is optional and is valid only if type – two-way-slm.
This can be set only when admin status is set to disabled.
The no form of the command reverts the value to the default.
Default
300 seconds
Parameters
period — [60|300]

OAM CLI Commands

loopback

loopback command
Item
Description
Syntax
loopback mac-address mep mep-id domain md-index association ma-index [send-count
send-count] [size data-size] [priority priority] [test-pattern-type test-pattern-type]
loopback multicast mep mep-id domain md-index association
ma-index [send-count send-count] [size data-size] [priority priority]]
Context
oam>eth-cfm
Description
This command sends a loopback message to another MIP/MEP
3HH-11982-AAAA-TQZZA
"FD 100/320Gbps NT and FX NT IHub System
Basics, Management and OAM Guide"
Issue: 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

73307360

Table of Contents