4.4.3 INV Function

With both the one-point and two-point scaling, use the INV function to re-
verse the inclination. However, the INV function reverses the inclination
around the 1/2 F.S. point, different from "SLOPE" of one-point scaling.
2.0000
Setting example
<Setting 1 mode>
<Display scale>
80
0
2mm
Press
to select "d-ScL".
Press
2.0000
1.0000
0
1mm
2mm
to select "d-Inv".