Chapter 5. Function Block Diagram (FBD)
MOV Operands
Parameter Description
Solve Order Calculated by the FBD editor.
EN
Enable
IN
The source of the data to copy into the output
Q. This can be either a constant or a variable
whose reference address is the location of the
first source data item to move.
IN must have the same data type as the
variable in the Q parameter.
If IN is a BOOL variable or a bit reference, an
%I, %Q, %M, or %T reference address need not
be byte-aligned, but 16 bits beginning with the
reference address specified are displayed
online.
LEN
The length of IN; the number of bits to move.
If IN is a constant and Q is BOOL:
1  LEN  16;
If IN is a constant and Q is not BOOL:
1  LEN  256.
All other cases: 1  LEN  32,767
LEN is also interpreted differently depending
on the data type of the Q location. For details,
see discussion under
ENO
Indicates whether the operation was
successfully completed.
If ENO = ON (1), the operation was initiated.
Results of the operation are indicated in the FT
output.
If ENO = OFF (0), the operation was not
performed. If EN was ON, the FT output
indicates an error condition. If EN was OFF, FT
is not changed.
Q
The location of the first destination data item.
Q must have the same data type as the
variable in the IN parameter.
If Q is a BOOL variable or a bit reference, an %I,
%Q, %M, or %T reference address does not
need to be byte-aligned, but 16 bits beginning
with the specified reference address are
displayed online.
256
PACSystems* RX7i, RX3i and RSTi-EP CPU Programmer's Reference Manual
Move Data
.
Allowed Types Allowed Operands Optional
NA
NA
BOOL variable data flow, I, Q, M, T,
G, S, SA, SB, SC,
discrete symbolic,
I/O variable
Bit reference in
R, P, L, AI, AQ, W,
a non-BOOL
non-discrete
variable
symbolic, I/O
variable
DINT, DWORD,
All. S, SA, SB, SC
INT, REAL,
allowed only for
LREAL, UINT,
WORD, DWORD,
WORD, or bit
BOOL types.
reference in a
non-BOOL
variable
Constant
Constant
BOOL variable data flow, I, Q, M, T,
G, discrete symbolic,
I/O variable
Bit reference in
I, Q, M, T, G, R, P, L, AI,
a non-BOOL
AQ, W, non-discrete
variable
symbolic, I/O
variable
DINT, DWORD,
data flow, I, Q, M, T,
INT, REAL,
S, SA, SB, SC, G, R, P,
LREAL, UINT,
L, AI, AQ, W,
WORD, or bit
symbolic, I/O
reference in a
variable
non-BOOL
variable
No
No
No
No
Yes
No
GFK-2950C