M800/M80/E80/C80 Series Alarm/Parameter Manual
4 MCP Alarms (Y)
Y06

mcp_no setting error

Details
The spindle/C axis "#1021 mcp_no (Drive unit I/F channel No. (servo))" and "#3031 smcp_no (Drive unit I/F
channel No. (spindle))" are not set to the same values.
Remedy
Check the values set for the following parameters.
"#1021 mcp_no (Drive unit I/F channel No. (servo))"
"#3031 smcp_no (Drive unit I/F channel No. (spindle))"
Y06
mcp_no setting error
Details
A random layout has been set while "#1154 pdoor" has been set to "1" in two-part system.
Remedy
Check the values set for the following parameters.
"#1021 mcp_no (Drive unit I/F channel No. (servo))"
"#3031 smcp_no (Drive unit I/F channel No. (spindle))"
Y06
mcp_no setting error
Details
The channel No. parameter is not within the setting range.
Remedy
Check the values set for the following parameters.
"#1021 mcp_no (Drive unit I/F channel No. (servo))"
"#3031 smcp_no (Drive unit I/F channel No. (spindle))"
Y07
Too many axes connected
Details
The number of axes connected to each channel exceeds the maximum number of connectable axes.
The exceeded number of axes per channel is displayed as alarm No.
x: Exceeded number of axes at drive unit interface channel 2 (0 to F)
y: Exceeded number of axes at drive unit interface channel 1 (0 to F)
This alarm also occurs when the drive unit is connected only with the 2nd channel without connecting with the
1st channel.
Remedy
Remove connected axes from the channel whose alarm No. is other than '0' for the number displayed as the
alarm No. Keep the number of connected axes to or less than the maximum that can be connected.
(Note 1) The number of axes is limited per each drive unit interface channel.
(Note 2) Maximum number of axes that can be connected differs depending on whether or not an expansion
unit is available or the setting of '#11012 16 axes for 1ch (Connecting 16 axes for 1ch)'.
With the expansion unit, up to eight axes can be connected to a channel. Without the expansion unit, up
to eight axes are allowed when '#11012 16 axes for 1ch (Connecting 16 axes for 1ch)' is set to '0', sixteen
axes when set to '1'.
(Note 3) If this alarm occurs, the alarm 'Y03 Message: Drive unit unequipped' will not occur.
(Note 4) This alarm is displayed taking precedence over the alarm 'Y08 Too many drive units connected' and
'Y09 Too many axisno connected'.