Arc Inside Min Ovr (For M System Only); Timing Sync System; Arc Inside Ovr On (For M System Only); Arc Inside Ovr Typ (For M System Only) - Mitsubishi Electric M800 Series Manual

Hide thumbs Also See for M800 Series:
Table of Contents

Advertisement

M800/M80/E80/C80 Series Alarm/Parameter Manual
15 User Parameters
#19418

Arc inside min ovr (for M system only)

[M8]
Set the minimum value of arc inside override.
R1/R2 come close to zero and the tool feed stops when the radius of tool center path(R1) is very smaller than
the radius of program path (R2).
When this parameter is set and R1/R2<=(parameter setting value), tool feed is F* (parameter setting value).
When this parameter is "0" or "100", the arc inside override is disabled.
---Setting range---
0 to 100 (%)
[C80]
Not used.
#19419

Timing sync system

Specify the counterpart part system for timing synchronization or for balance cut when the part system No.
is omitted.
Set the part system No. in a way that reflects the combination of two part systems as follows.
(Example) Timing synchronization between Part systems 1 and 3
Enter 3 for the 1st part system, and enter 1 for the 3rd part system.
(Note) When 0 is set, timing synchronization is carried out between Part systems 1 and 2.
---Setting range---
0 to 8
#19420

Arc inside ovr ON (for M system only)

[M8]
Select the enable conditions for the arc inside override.
0: Enable during tool radius compensation
1: Enable during tool radius compensation and automatic corner override
(Note) When M2 format is in use, the arc inside override enables during tool radius compensation, regardless
of the setting value of this parameter.
[C80]
Not used.
#19421

Arc inside ovr typ (for M system only)

[M8]
Specify the type of arc inside override.
0: Type 1
Arc inside override during circular cutting is invalid.
1: Type 2
Arc inside override during circular cutting is valid.
[C80]
Not used.
#19425
ManualB Std R1
Set a radius used as standard for the rotary axis speed.
When the setting value of #19425 is larger than that of "#19427 ManualB Std R2", #19425 setting will be used
as surface speed control standard radius 2: #19427 setting will be used as surface speed control standard
radius 1.
---Setting range---
0 to 99999.999 (mm)