Remote I/O Unit - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

1
2
3)
/35.7 /37.5 /34.3 /36.7 / +24Vdevicenet;5
/35.7 /37.5 /34.4 /36.7 / 0Vdevicenet;5
/60.5 / V-
/60.5 / CAN_L
/60.5 / CAN_H
/60.5 / V+
/60.5 / DRAIN
OR PREVIOUS
I/O UNIT
1) JUMPERS PLACED ACCORDING TO
THE ACTUAL NODE ADDRESS.
2) RESISTANS 120 OHM SHALL ALWAYS
BE CONNECTED IN THE FIRST AND THE
LAST CONNECTOR IN THE CAN-BUS CIRCUIT.
3) CONNECTED IN THE LAST CONNECTOR IN THE
CAN-BUS CIRCUIT.
Latest revision:
Prepared by, date:
Approved by, date:
3
4
TO NEXT
I/O UNIT
2)
120 ohm
2
1

REMOTE I/O UNIT

-I/Ox
-X5
NAC
1 1
2 2
4 4
5 5
0V
3 3
NA0
6 6
NA1
7 7
1)
NA2
8 8
NA3
9 9
NA4
10
10
NA5
11
11
12
12
5
-X8
1 1
1
2 2
-X9
1 1
2 2
3 3
3 3
4 4
4 4
Lab/Office:
CONTROL SYS. IRC5 M2004 DESIGN 06
REMOTE I/O UNIT
6
7
LINE 1 (BLUE)
LINE 2 (CLEAR)
(BLUE)
(CLEAR)
Status:
2008-07-17
Plant:
Location:
Approved
Sublocation:
Document no.
3HAC024480-004
8
REMOTE I/O IN
REMOTE I/O OUT
=
CAB
+
CM
+
SLO.4
Rev. Ind
Page 69