2 Installation and Commissioning, IRC5
2.9.7. Installation of Euromap and SPI
Continued
E
G
H
K
Location of Euromap harness in the Dual Cabinet
xx0500002634
A
B
C
D
F
H
J
Required equipment for Euromap 67 (Option no. 671-2)
Equipment
Cabling
124
Relay 24K1 and Relay 24K2
Position switch terminal XT13
Euromap 67: Digital 24 VDC I/O (I/O 1) Euromap 12 and SPI: Digital Relay
I/O
Connector XS13
Connector A21.X5, on Panel board
Connector A21.X1, on Panel board
Connector A21.X2, on Panel board
XS13 connector
Euromap 67: Digital 24 VDC I/O (I/O 1) Euromap 12 and SPI: Digital Relay
I/O
XT31
Connector XS13 Relay 24K1 Relay 24K2
Art. number
Description
3HAC025478-001
internal in cabinet
Note
Single Cabinet
Continues on next page
3HAC021313-001 Revision: K