Power Modules
3.1 Power Modules Blocksize (PM340)
Line voltage 3-ph. 380 V to 480 V AC
PM340
PM340 with integrated
line filter
Line supply connection
U1/L1, V1/L2, W1/L3
Motor connection
U2, V2, W2
DC link connection,
connection for braking
resistor DCP/R1, DCN,
R2
PE connection
Max. motor cable length
2)
Degree of protection
Depth
- PM340 with Control Unit
CU310
- PM340 with CUA31
Frame size
Weight, approx.
1)
2)
Table 3-11
Technical data PM340, Part 3
Line voltage 3-ph. 380 V to 480 V AC
PM340
PM340 with integrated
line filter
Rated output current I
n
Base load current I
H
Output current for S6 duty
(40%) l
S6
Max. output current I
max
Rated power based on I
n
Rated power based on I
H
Rated pulse frequency
Efficiency η
3-32
6SL3210-
1SE11-3UA0
6SL3210-
1SE11-3AA0
Screw terminals
for cable cross-
sections
1.0 to 2.5 mm
2
Screw terminals
for cable cross-
sections
1.0 to 2.5 mm
2
Screw terminals
for cable cross-
sections
1.0 to 2.5 mm
2
at the housing
with M 4 screw
m
50 (shielded)
75 (non-shielded)
IP20 or IPXXB
mm
234.6 (9.23)
175.3 (6.90)
A
kg
1.2
The input current depends on the motor load and line impedance. The input currents apply for a load with the rated power (based on In)
for a line impedance corresponding to uk = 1%.
Max. motor cable length 50 m (shielded), 100 m (non-shielded), for Power Modules PM340 with integrated line filter to maintain the limit
values of EN 61800-3 Category C2.
6SL3210- 1SE16-0UA0
6SL3210- 1SE16-0AA0
A
5.9
A
5.2
A
6.4
A
11.8
kW
2.2
kW
2.2
kHz
4
0.97
1SE11-7UA0
1SE12-2UA0
1SE11-7AA0
1SE12-2AA0
Screw terminals
Screw terminals
for cable cross-
for cable cross-
sections
sections
1.0 to 2.5 mm
1.0 to 2.5 mm
2
Screw terminals
Screw terminals
for cable cross-
for cable cross-
sections
sections
1.0 to 2.5 mm
1.0 to 2.5 mm
2
Screw terminals
Screw terminals
for cable cross-
for cable cross-
sections
sections
1.0 to 2.5 mm
1.0 to 2.5 mm
2
at the housing
at the housing
with M 4 screw
with M 4 screw
50 (shielded)
50 (shielded)
75 (non-shielded)
75 (non-shielded)
IP20 or IPXXB
IP20 or IPXXB
234.6 (9.23)
234.6 (9.23)
175.3 (6.90)
175.3 (6.90)
A
A
1.2
1.2
1SE17-7UA0
1SE21-0UA0
1SE17-7AA0
1SE21-0AA0
7.7
10.2
6.8
9.1
8.3
10.8
15.4
20.4
3
4
3
4
4
4
0.97
0.97
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
1SE13-1UA0
1SE14-1UA0
1SE13-1AA0
1SE14-1AA0
Screw terminals
Screw terminals
for cable cross-
for cable cross-
sections
sections
1.0 to 2.5 mm
1.0 to 2.5 mm
2
2
Screw terminals
Screw terminals
for cable cross-
for cable cross-
sections
sections
1.0 to 2.5 mm
1.0 to 2.5 mm
2
2
Screw terminals
Screw terminals
for cable cross-
for cable cross-
sections
sections
1.0 to 2.5 mm
1.0 to 2.5 mm
2
2
at the housing
at the housing
with M 4 screw
with M 4 screw
50 (shielded)
50 (shielded)
75 (non-shielded)
75 (non-shielded)
IP20 or IPXXB
IP20 or IPXXB
234.6 (9.23)
234.6 (9.23)
175.3 (6.90)
175.3 (6.90)
A
A
1.2
1.2
1SE21-8AA0
1SE22-5UA0
1SE21-8UA0
1SE22-5AA0
18
25
14
21
19.6
27.8
26.4
38
7.5
11
5.5
7.5
4
4
0.97
0.97
Equipment Manual AC Drive