2 Parameters
2.2 List of parameters
p2151[0...n]
CI: Speed setpoint for messages/signals / n_set for msg
VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for the speed setpoint for the following messages:
"Speed setpoint - actual value deviation within tolerance t_off" (BO: r2197.7)
"Ramp-up/ramp-down completed" (BO: r2199.5)
"|n_set| < p2161" (BO: r2198.4)
"n_set > 0" (BO: r2198.5)
Dependency:
Refer to: r2197, r2198, r2199
p2153[0...n]
Speed actual value filter time constant / n_act_filt T
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0 [ms]
Description:
Sets the time constant of the PT1 element to smooth the speed / velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages and
signals.
Dependency:
Refer to: r2169
p2154[0...n]
CI: Speed setpoint 2 / n_set 2
VECTOR_G
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for speed setpoint 2.
The sum of p2151 and p2154 is used for the following messages/signals:
"Speed setpoint - actual value deviation within tolerance t_off" (r2197.7)
"Speed setpoint - actual value deviation within tolerance t_on" (r2199.4)
"Ramp-up/ramp-down completed" (r2199.5)
Dependency:
Refer to: p2151, r2197, r2199
p2155[0...n]
Speed threshold 2 / n_thresh val 2
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the speed threshold value for the following messages:
"|n_act| < = speed threshold value 2" (BO: r2197.1)
"|n_act| > speed threshold value 2" (BO: r2197.2)
552
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2000
Max
-
Calculated: -
Dyn. index: DDS, p0180
Unit group: -
Scaling: -
Max
1000000 [ms]
Calculated: -
Dyn. index: CDS, p0170
Unit group: -
Scaling: p2000
Max
-
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Unit group: 3_1
Scaling: -
Max
210000.00 [rpm]
List Manual (LH2), 07/2016, A5E03263479A
Access level: 3
Func. diagram: 8011
Unit selection: -
Expert list: 1
Factory setting
1170[0]
Access level: 3
Func. diagram: 8010
Unit selection: -
Expert list: 1
Factory setting
0 [ms]
Access level: 3
Func. diagram: 8010
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
900.00 [rpm]
SINAMICS G130/G150