ELECTRICAL CHARACTERISTICS

ABSOLUTE MAXIMUM RATINGS

Parameter
Supply Voltage
Operating Tempatature
Storage Temperature
NOTE: Absolute Maximum Ratings may cause critical device failure by above table beyond limits.

RECOMMENDED OPERATING RANGES

Parameter
Operating Voltage
Supply
100Base-TX
Current
10Base-T
Power-Down Mode
Auto-Negotiation
Ambient Operating Temperature
X-tal OSC Frequency
X-tal OSC Frequency Tolerance
NOTE: The device is guaranteed within above limits.
8-2
Table 8-1. Absolute Maximum Ratings (T A = 25 °C)
Symbol
V
GND-0.3
DD
T
OP
T
STG
Table 8-2. Recommended Operating Conditions
Symbol
V
DD
I
100TX
I
10T
I
PD
I
AN
T
OP
f
OSC
f
OT
KS8910 100/10 Mbps ETHERNET TRANSCEIVER
Min
0
-65
Conditions
-
-
-
-
-
-
CL = 15pF
-
Preliminary Spec. ver
Max
3.8
70
150
Min
Typ
Max
3.1
3.3
3.5
-
180
-
200
-
300
-
300
0
-
70
-
25
-50
-
50
1.4
Unit
V
°C
°C
Unit
V
-
mA
-
mA
-
uA
-
mA
°C
-
MHz
PPM