Yamaha CL5 Reference Manual page 109

Digital
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

◆ MONITOR FADER field
10
MONITOR FADER LEVEL knob
Indicates the monitor level. Press this knob to adjust the monitor level using the
multifunction knob. Or, press the Centralogic section bank select [STEREO] key, and
then use the monitor fader to adjust the level.
A
FADER ASSIGN indicator
Indicates the fader(s) to which the monitor level is assigned. Indicator assignments are
as follows:
MASTER A
MASTER A fader only
MASTER A+
MASTER A, as well as MASTER B fader and Custom fader bank
MASTER B
MASTER B fader only
MASTER B+
MASTER B, as well as Custom fader bank
CUSTOM
One of the Custom fader bank faders
CUSTOMs
Multiple Custom fader bank faders
◆ MONITOR DELAY field
This field enables you to specify the monitor delay setting by which the monitor out signal is
delayed.
B
AUTO BYPASS button
Turn this on to automatically bypass monitor delay when the cue is on.
C
MONITOR DELAY knob
Indicates the currently-specified delay time. The millisecond value is indicated above the
knob, and the delay time value in currently-selected units and the currently-selected
scale type are indicated below the knob. However, if the scale is set to ms, the delay time
value is not shown above the knob.
Press this knob to control the level using the multifunction knobs.
◆ Meter field
Indicates the monitor output level.
D
Meters
This field indicates the output level of the monitor L/R/C
E
F
channels.
106
MONITOR OUT PATCH button
Press this button to open the PORT SELECT window, in which you can select an output
port to patch to the monitor out L/R/C channels.
DANTE 1-64
Output channels 1-64 to audio network
OMNI1-8
OMNI OUT jacks 1-8
DIGI OUT L/R
DIGITAL OUT jack on the CL unit
SLOT1-1 - SLOT3-16
Output channels 1-16 of an I/O card installed in slots 1-3
NOTE
• You can specify output ports only for MONITOR OUT L and R, and monitor through two speakers.
• If you have not specified an output port for MONITOR OUT C, selecting the MONO (C) button or
LCR button as the monitor source will automatically cause the MONO channel signal to be
distributed to MONITOR OUT L/R.
ASSIGN field
If you have selected DEFINE in the SOURCE SELECT field, you can use the ASSIGN field
to specify multiple monitor sources. The following table shows the monitor sources that
you can select in the ASSIGN field.
MIX 1-24
Output signals of MIX channels 1-24
MTRX 1-8
MATRIX buses 1 - 8 output signals
STEREO
STEREO L/R channel output signals
MONO (C)
MONO channel output signal
OMNI IN jacks 1 - 8 input signals (per two
OMNI 1-2 - OMNI 7-8
channels)
PB OUT
Recorder's PLAYBACK OUT signals
NOTE
You can select a maximum of eight monitor sources in the ASSIGN field. If you select eight
monitor sources, no further selections will be possible. Turn off the buttons of unneeded sources.
Monitor and Cue functions