Siemens SIMATIC S5 Manual page 106

Ip 267 stepper motor controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Application Examples
Table 6-2. Configuration Message Frame for the Path C to A
Byte
Address
0
QB 88
Limit switch configuration
1
QB 89
2
QB 90
3
QB 91
6-30
General meaning
Multiplier for the
start/stop rate (SS),
SS can assume values
from 1 to 255
"STOP" mode
Time interval (TI) for
frequency change
TI can assume values
from 1 to 255
Base value (BV) for the
frequency
IP 267
Configuration data for
the path C to A
SS =
8
QB 88 =
00001000
QB 88 =
08
H
EK =
1
BA1=0,
BA0=0
QB 89 =
00000010
QB 89 =
02
H
TI =
7
QB 90 =
00000111
QB 90 =
07
H
BV =
40
QB 91 =
00000100
QB 91 =
04
H
EWA 4NEB 812 6061-02a

Hide quick links:

Advertisement

Table of Contents
loading