GE UR Series B30 Instruction Manual page 433

Bus differential system
Hide thumbs Also See for UR Series B30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 25 of 51)
ADDR
REGISTER NAME
7544
Disconnect Switch 1 Mode
7545
Disconnect Switch 1 Open
7546
Disconnect Switch 1 Block Open
7547
Disconnect Switch 1 Close
7548
Disconnect Switch 1 Block Close
7549
Disconnect Switch 1 Phase A / Three-Pole Closed
754A
Disconnect Switch 1 Phase A / Three-Pole Opened
754B
Disconnect Switch 1 Phase B Closed
754C
Disconnect Switch 1 Phase B Opened
754D
Disconnect Switch 1 Phase C Closed
754E
Disconnect Switch 1 Phase C Opened
754F
Disconnect Switch 1 Operate Time
7550
Disconnect Switch 1 Alarm Delay
7552
Disconnect Switch 1 Events
7553
Reserved (2 items)
7555
...Repeated for Disconnect Switch 2
756A
...Repeated for Disconnect Switch 3
757F
...Repeated for Disconnect Switch 4
7594
...Repeated for Disconnect Switch 5
75A9
...Repeated for Disconnect Switch 6
75BE
...Repeated for Disconnect Switch 7
75D3
...Repeated for Disconnect Switch 8
75E8
...Repeated for Disconnect Switch 9
75FD
...Repeated for Disconnect Switch 10
7612
...Repeated for Disconnect Switch 11
7627
...Repeated for Disconnect Switch 12
763C
...Repeated for Disconnect Switch 13
7651
...Repeated for Disconnect Switch 14
7666
...Repeated for Disconnect Switch 15
767B
...Repeated for Disconnect Switch 16
7690
...Repeated for Disconnect Switch 17
76A5
...Repeated for Disconnect Switch 18
76BA
...Repeated for Disconnect Switch 19
76CF
...Repeated for Disconnect Switch 20
76E4
...Repeated for Disconnect Switch 21
76F9
...Repeated for Disconnect Switch 22
770E
...Repeated for Disconnect Switch 23
7723
...Repeated for Disconnect Switch 24
Thermal Overload Protection (Read/Write Settings) (2 modules)
7738
Thermal Protection 1 Function
7739
Thermal Protection 1 Source
773A
Thermal Protection 1 Base Current
773B
Thermal Protection 1 K Factor
773C
Thermal Protection 1 Trip Time Constant
773D
Thermal Protection 1 Reset Time Constant
773E
Thermal Protection 1 Minimum Reset Time
773F
Thermal Protection 1 Reset
7740
Thermal Protection 1 Block
7741
Thermal Protection 1 Target
7742
Thermal Protection 1 Events
7743
Reserved (2 items)
7745
Repeated for Thermal Protection 2
Ohm Inputs (Read/Write Setting) (2 modules)
7840
Ohm Inputs 1 Function
GE Multilin
RANGE
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65.535
0 to 65.535
0 to 1
---
0 to 1
0 to 5
0.2 to 3
1 to 1.2
0 to 1000
0 to 1000
0 to 1000
0 to 65535
0 to 65535
0 to 2
0 to 1
---
0 to 1
B30 Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F003
---
1
F102
---
---
F001
---
1
F102
---
1
F167
pu
0.01
F001
---
0.05
F001
min.
1
F001
min.
1
F001
min.
1
F001
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F102
DEFAULT
0 (3-Pole)
0
0
0
0
B
0
0
0
0
0
0
70
0
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
80
110
45
45
20
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
B-33