GE L90 Instruction Manual page 397

Line differential relay ur series
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 12 of 41)
ADDR
REGISTER NAME
40C8
IEC 61850 Logical Device Name
40D0
GSSE Function
40D1
Reserved (15 items)
40E0
TCP Port Number for the IEC 60870-5-104 Protocol
40E1
IEC 60870-5-104 Protocol Function
40E2
IEC 60870-5-104 Protocol Common Address of ASDU
40E3
IEC 60870-5-104 Protocol Cyclic Data Trans. Period
40E4
IEC 60870-5-104 Sources used in M_ME_NC_1 point list
40E5
IEC 60870-5-104 Current Default Threshold
40E6
IEC 60870-5-104 Voltage Default Threshold
40E7
IEC 60870-5-104 Power Default Threshold
40E8
IEC 60870-5-104 Energy Default Threshold
40E9
IEC 60870-5-104 Other Default Threshold
40EA
IEC 60870-5-104 Client Address (5 items)
40FE
IEC 60870-5-104 Communications Reserved (2 items)
4100
DNP Binary Input Block of 16 Points (58 items)
4140
DNP Object 1 Default Variation
4141
DNP Object 2 Default Variation
4142
DNP Object 20 Default Variation
4143
DNP Object 21 Default Variation
4144
DNP Object 22 Default Variation
4145
DNP Object 23 Default Variation
4146
DNP Object 30 Default Variation
4147
DNP Object 32 Default Variation
Simple Network Time Protocol (Read/Write Setting)
4168
Simple Network Time Protocol (SNTP) Function
4169
Simple Network Time Protocol (SNTP) Server IP Address
416B
Simple Network Time Protocol (SNTP) UDP Port Number
Data Logger Commands (Read/Write Command)
4170
Data Logger Clear
Data Logger (Read/Write Setting)
4180
Data Logger Rate
4181
Data Logger Channel Settings (16 items)
Clock (Read/Write Command)
41A0
Real Time Clock Set Time
Clock (Read/Write Setting)
41A2
SR Date Format
41A4
SR Time Format
41A6
IRIG-B Signal Type
41A7
Clock Events Enable / Disable
Fault Report Commands (Read/Write Command)
41B2
Fault Reports Clear Data Command
Oscillography (Read/Write Setting)
41C0
Oscillography Number of Records
41C1
Oscillography Trigger Mode
41C2
Oscillography Trigger Position
41C3
Oscillography Trigger Source
41C4
Oscillography AC Input Waveforms
41D0
Oscillography Analog Channel n (16 items)
4200
Oscillography Digital Channel n (63 items)
Trip and Alarm LEDs (Read/Write Setting)
4260
Trip LED Input FlexLogic Operand
4261
Alarm LED Input FlexLogic Operand
GE Multilin
RANGE
---
0 to 1
0 to 1
1 to 65535
0 to 1
0 to 65535
1 to 65535
1 to 6
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 4294967295
0 to 1
0 to 58
1 to 2
1 to 2
0 to 3
0 to 3
0 to 3
0 to 3
1 to 5
0 to 5
0 to 1
0 to 4294967295
1 to 65535
0 to 1
0 to 7
---
0 to 235959
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 1
1 to 64
0 to 1
0 to 100
0 to 65535
0 to 4
0 to 65535
0 to 65535
0 to 65535
0 to 65535
L90 Line Differential Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F203
---
1
F102
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F001
---
1
F197
---
1
F001
---
1
F001
---
1
F523
---
1
F524
---
1
F523
---
1
F523
---
1
F001
---
1
F525
---
1
F102
---
1
F003
---
1
F001
---
1
F126
---
1
F178
---
---
F600
---
1
F050
---
1
F051
---
1
F052
---
1
F114
---
1
F102
---
1
F126
---
1
F001
---
1
F118
0 (Auto. Overwrite)
%
1
F001
---
1
F300
---
1
F183
2 (16 samples/cycle)
---
1
F600
---
1
F300
---
1
F300
---
1
F300
DEFAULT
"IECDevice"
1 (Enabled)
0
2404
0 (Disabled)
B
0
60
1
30000
30000
30000
30000
30000
0
0
0 (Not Used)
2
2
0 (1)
0 (1)
0 (1)
0 (1)
1
0 (1)
0 (Disabled)
0
123
0 (No)
1 (1 min)
0
0
0
0
0 (None)
0 (Disabled)
0 (No)
15
50
0
0
0
0
0
B-19

Advertisement

Table of Contents
loading

Table of Contents