APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 33 of 65)
ADDR
REGISTER NAME
63C2
Negative Sequence Instantaneous Overcurrent 1 Pickup
63C3
Negative Sequence Instantaneous Overcurrent 1 Delay
63C4
Negative Sequence Instantaneous OC 1 Reset Delay
63C5
Negative Sequence Instantaneous Overcurrent 1 Block
63C7
Negative Sequence Instantaneous Overcurrent 1 Target
63C8
Negative Sequence Instantaneous Overcurrent 1 Events
63C9
Reserved (8 items)
63D1
...Repeated for Negative Sequence Instantaneous OC 2
Negative Sequence Overvoltage (Read/Write Grouped Setting) (3 modules)
6440
Negative Sequence Overvoltage 1 Function
6441
Negative Sequence Overvoltage 1 Source
6442
Negative Sequence Overvoltage 1 Pickup
6443
Negative Sequence Overvoltage 1 Pickup Delay
6444
Negative Sequence Overvoltage 1 Reset Delay
6445
Negative Sequence Overvoltage 1 Block
6447
Negative Sequence Overvoltage 1 Target
6448
Negative Sequence Overvoltage 1 Events
6449
...Repeated for Negative Sequence Overvoltage 2
6452
...Repeated for Negative Sequence Overvoltage 3
Time of Day Timer (Read/Write Setting) (5 modules)
6570
Time of Day Timer 1 Function
6571
Time of Day Timer 1 Start Time
6573
Time of Day Timer 1 Stop Time
6575
Time of Day Timer 1 Targets
6576
Time of Day Timer 1 Events
6577
...Repeated for Time of Day Timer 2
657E
...Repeated for Time of Day Timer 3
6585
...Repeated for Time of Day Timer 4
658C
...Repeated for Time of Day Timer 5
Phase Undervoltage (Read/Write Grouped Setting) (3 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7008
Phase Undervoltage 1 Target
7009
Phase Undervoltage 1 Events
700A
Phase Undervoltage 1 Measurement Mode
700B
Reserved (6 items)
7011
...Repeated for Phase Undervoltage 2
7022
...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting) (3 modules)
7040
Phase Overvoltage 1 Function
7041
Phase Overvoltage 1 Source
7042
Phase Overvoltage 1 Pickup
7043
Phase Overvoltage 1 Delay
7044
Phase Overvoltage 1 Reset Delay
7045
Phase Overvoltage 1 Block
7047
Phase Overvoltage 1 Target
7048
Phase Overvoltage 1 Events
7049
...Repeated for Phase Overvoltage 2
GE Multilin
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
C70 Capacitor Bank Protection and Control System
RANGE
UNITS
STEP
0 to 30
pu
0.001
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 1.25
pu
0.001
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 2359
---
1
0 to 2359
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 3
pu
0.001
0 to 1
---
1
0 to 600
s
0.01
0 to 3
pu
0.001
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 5
---
1
0 to 3
pu
0.001
0 to 600
s
0.01
0 to 600
s
0.01
---
1
0 to 2
---
1
0 to 1
---
1
B.4 MEMORY MAPPING
FORMAT
DEFAULT
F001
1000
F001
0
F001
0
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
F001
300
F001
50
F001
50
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F050
0
F050
2359
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F167
0 (SRC 1)
F001
1000
F111
0 (Definite Time)
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F186
0 (Phase to
Ground)
F001
0
F102
0 (Disabled)
F167
0 (SRC 1)
F001
1000
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
B-41
B