DC link components
5.1 Blocksize
Line voltage 1-phase 200 VAC -10% to 240 VAC +10%
Manufacturer
Manufacturer's
designation
Manufacturer order
number
Thermostatic switch (NC
contact)
Maximum contact load
connecting cable
Weight
x = A: Power Module with integrated line filter, x = U: Power Module without integrated line filter
1)
188
GWHS
167-60x30-K
IP20 200. ±7%
37.5 W TS KA
100 cm
JJY 02 31467 2
0008
250 VAC / 2.5 A
kg
0,5
Heine Resistors GmbH
GWHS
GWHS
217-60x30-K
337-60x30-K
IP20 68. ±7%
IP20 37. ±7%
110 W TS KA
200 W TS KA
100 cm
100 cm
JJY 02 31517 2
JJY 02 31637 2
0007
0018
250 VAC / 2.5 A
250 VAC / 2.5 A
0,7
1,1
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
GWHS
337-120x30-K
IP20 20. ±7%
375 W TS KA
100 cm
JJY 02 34337 2
0001
250 VAC / 2.5 A
2,2