Chapter 5 - Parameter List

5.3 Function 2 Group [FU2]

Code
Description
FU2-00 Jump to desired code #
FU2-01 Previous Fault History 1
FU2-02 Previous Fault History 2
FU2-03 Previous Fault History 3
FU2-04 Previous Fault History 4
FU2-05 Previous Fault History 5
FU2-06 Erase Fault History
FU2-07 Dwell Frequency
FU2-08 Dwell Time
Frequency Jump
FU2-10
Selection
FU2-11
18
Jump Frequency 1 Low
FU2-12 Jump Frequency 1 High
FU2-13 Jump Frequency 2 Low
FU2-14 Jump Frequency 2 High
FU2-15 Jump Frequency 3 Low
FU2-16 Jump Frequency 3 High
Start Curve for S-Curve
FU2-17
Accel/Dedel Pattern
End Curve for S-Curve
FU2-18
Accel/Dedel Pattern
Input/Output Phase Loss
FU2-19
Protection
FU2-20 Power ON Start Selection
FU2-21 Restart after Fault Reset
FU2-22 Speed Search Selection
Current Limit Level
FU2-23
During Speed Search
P Gain
FU2-24
During Speed Search
I Gain
FU2-25
During speed search
Number of Auto Restart
FU2-26
Attempt
Delay Time
FU2-27
Before Auto Restart
FU2-28 Speed Search Hold Time
FU2-30 Rated Motor Selection
18
Code FU2-11 through FU2-16 appears only when FU2-10 is set to ' Yes' .
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Keypad Display
LCD
7-Segment
Not displayed
Jump code
Last trip-1
01
Last trip-2
02
Last trip-3
03
Last trip-4
04
Last trip-5
05
Erase trips
06
Dwell freq
07
Dwell time
08
Jump freq
10
Jump lo 1
11
Jump Hi 1
12
Jump lo 2
13
Jump Hi 2
14
Jump lo 3
15
Jump Hi 3
16
Start Curve
17
End Curve
18
Trip select
19
Power-on run
20
RST restart
21
Speed Search
22
SS Sup-Curr
23
SS P-gain
24
SS I-gain
25
Retry number
26
Retry Delay
27
SS blk time
28
Motor select
30
60
Setting Range
LCD
7-Segment
1 to 99
Not available
By pressing [PROG] and [? ] key,
the frequency, current, and
operational status at the time of fault
can be seen.
No
0
Yes
1
FU1-22 to FU1-20
0 to 10 [sec]
No
0
Yes
1
0 to FU2-12
FU2-11 to FU1-20
0 to FU2-14
FU2-13 to FU1-20
0 to FU2-16
FU2-15 to FU1-20
0 to 100 [%]
0 to 100 [%]
00 to 11
(Bit Set)
No
0
Yes
1
No
0
Yes
1
0000 to 1111
(Bit Set)
80 to 200 [%]
0 to 9999
0 to 9999
0 to 10
0 to 60 [sec]
0 to 60 [sec]
0.75kW
0
Adj.
Factory
During
Units
Page
Default
Run
1
1
Yes
99
-
None
-
99
-
No
Yes
0.01
5.00 [Hz]
No
100
0.1
0.0 [sec]
No
-
No
No
0.01
10.00 [Hz]
Yes
0.01
15.00 [Hz]
Yes
100
0.01
20.00 [Hz]
Yes
0.01
25.00 [Hz]
Yes
0.01
30.00 [Hz]
Yes
0.01
35.00 [Hz]
Yes
1
40%
No
101
1
40%
No
101
-
00
Yes
101
-
No
Yes
101
-
No
Yes
102
-
0000
No
1
150 [%]
Yes
102
1
100
Yes
1
200
Yes
1
0
Yes
103
0.1
1.0 [sec]
Yes
103
0.1
1.0 [sec]
No
104
-
No
104
19