APPENDIX A - FUNCTIONS BASED ON USE

Set the function properly according to the load and operating conditions. Application and related functions are listed in
the following table.
Use
Accel/Decel Time, Pattern Adjustment
Reverse Rotation Prevention
Minimum Accel/Decel Time
Accel/Decel at Continuous Rating Range
Braking Operation Adjustment
Operations for Frequencies Over 60 Hz
Selecting an Appropriate Output
Characterist i cs for the Load
Motor Output Torque Adjustment
Output Frequency Limit
Motor Overheat Protection
Multi Step Operation
Jog Operation
Frequency Jump Operation
Timing the Electronic Brake Operation
Displaying the Rotating Speed
Function Alteration Prevention
Energy Saving
Auto Restart Operation After Alarm Stop
2
Motor Operation
nd
PID Feedback Operation
Frequency Reference Signal and Output
Adjusting
Define the Multi-Function Input Terminals
Define the Multi-Function Input Terminals
Commercial Line ⇔ inverter Switchover
Operation
Frequency Meter Calibration
Operate by Communicating with a Computer
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
Related Parameter Code
DRV-01 [Acceleration Time], DRV-02 [Deceleration Time],
FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]
FU1-03 [Forward, Reverse Prevention]
FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]
FU1-05 [Acceleration Pattern], FU1-06 [Deceleration Pattern]
FU1-07 [Stop Method], FU1-08~11 [DC Braking],
FU1-12~13 [DC braking at start]
FU1-20 [Maximum Frequency],
FU1-25 [Frequency Upper Limit],
I/O-05 [Frequency Corresponding to Max. Voltage of V1],
I/O-10 [Frequency Corresponding to Max. Current of I]
FU1-20 [Maximum Frequency],
FU1-21 [Base Frequency]
FU1-22 [Starting Frequency],
FU1-26~28 [Torque Boost],
FU1-59~60 [Stall Prevention],
FU2-30 [Rated Motor]
FU1-23~25 [Frequency Upper/Lower Limit],
I/O-01~10 [Analog Frequency Setting]
FU1-50~53 [Electronic Thermal], FU2-30 [Rated Motor]
I/O-12~14 [Define the Multi Function Input Terminals],
I/O-20~27 [Jog, Multi Step Frequency],
FU1-23~25 [Frequency Upper/Lower Limit]
I/O-20 [Jog Frequency]
FU2-10~16 [Frequency Jump]
I/O-42~43 [Frequency Detection Level],
I/O-44 [Multi Function Output]
DRV-04 [Motor Speed],
FU2-74 [Motor RPM Display Gain]
FU2-94 [Parameter Lock]
FU1-39 [Energy Saving]
FU2-27~28 [Auto Retry]
FU2-81~90 [2
Function]
nd
FU2-50~54 [PID Operation]
I/O-01~10 [Analog Frequency Setting]
I/O-12~14 [Define the Multi-Function Input Terminals]
I/O-44 [Multi Function Auxiliary Contact Output Setting]
I/O-12~14 [Define the Multi-Function Input Terminals],
I/O-44 [Multi-Function Auxiliary Contact Output Setting]
I/O-40~41 [FM Output]
I/O-46 [Inverter No.],
I/O-47 [communication Speed],
I/O-48~49 [Loss of Reference]